UGR Table
See the standard UGR table of one IES or LDT file, by CIE 190 or the CIE 117 tabular method. You need no account.
On this page
Calculate the table
Open Tools, then UGR Table. Drop one IES or LDT file, or choose it with Calculate. From a View page, Calculate UGR table uses the same file.
Read the table
Each row is a room size, in multiples of the height H between the eye and the luminaire. The columns are five sets of reflectances (ceiling, walls, and floor or reference plane), seen crosswise and endwise. The framed values are the reference room, 4H × 8H at 70/50/20: the value that a datasheet usually quotes. The notes under the table say what the file leaves open.
A luminaire that is symmetric about both main planes, such as most panels, gets the table of CIE 190, with the luminaires 1H apart. Another luminaire, such as a wall washer, a spotlight or an asymmetric luminaire, gets the tabular method of CIE 117. The line under the table names the method.
Where your file goes
The UGR Table reads your file in your browser where it can. IESDesk keeps no copy of the file, and the file stays unchanged. The privacy notice has the details.