Every tool for your IES and LDT files, for one file or many at once.

Try most tools on one file with no account. A free account takes up to 100 files per batch or job.

Enterprise adds higher limits, report branding and custom diagram themes.

On this page

Edit metadata

Change the product name, the catalogue number, the manufacturer and the other header text in many IES or LDT files at once. You can open IES and LDT files in one drop, and each format gets its own table. Your files stay in this browser unless you choose to upload them. Edit in a table, or download the text as a CSV or Excel sheet, change it there and upload it again. You get one ZIP file with the edited files of each format. IESDesk checks each file before the download, and the light data stays as measured.

See the metadata of one file, no account: View

Many files: Sign up free

Diagrams

Draw polar, Cartesian, cone and isolux diagrams. Free uses the Minimal style. Choose SVG, PNG or JPG, up to 300 dpi. Draw the cone as a beam for spotlights. Enterprise adds all styles and custom themes. You get one ZIP file for each format. IESDesk emails you when the diagrams are ready.

Polar intensity diagram, C0–C180 and C90–C270Peak intensity 300 cd/klm at gamma 0 degrees. The outer ring is 300 cd/klm.0°30°30°60°60°90°90°120°120°150°150°180°100200300cd/klmC0–C180C90–C270
Polar: the strength of the light in each direction.
Cartesian intensity diagram, C0–C180 and C90–C270Peak intensity 300 cd/klm at gamma 0 degrees. The top line is 300 cd/klm.-180°-150°-120°-90°-60°-30°0°30°60°90°120°150°180°100200300cd/klmC0–C180C90–C270
Cartesian: the same values on straight axes.
Cone diagram, beam angle 40.0°At 1 m: diameter 0.73 m, 2000 lux. At 2 m: diameter 1.46 m, 500 lux. At 3 m: diameter 2.18 m, 222 lux. At 4 m: diameter 2.91 m, 125 lux. At 5 m: diameter 3.64 m, 80 lux.HeightDiameterCentre40.0°1 mØ 0.73 m2000 lx2 mØ 1.46 m500 lx3 mØ 2.18 m222 lx4 mØ 2.91 m125 lx5 mØ 3.64 m80 lx
Cone: the light on the floor at each height.
Cone diagram, beam look, beam angle 40.0°At 1 m (3.28 ft): beam width 0.73 m (2.39 ft), 2000 lux (186 fc). At 2 m (6.56 ft): beam width 1.46 m (4.78 ft), 500 lux (46 fc). At 3 m (9.84 ft): beam width 2.18 m (7.16 ft), 222 lux (21 fc). At 4 m (13.1 ft): beam width 2.91 m (9.55 ft), 125 lux (12 fc). At 5 m (16.4 ft): beam width 3.64 m (11.9 ft), 80 lux (7.4 fc).DistanceBeam widthIlluminanceat the centre40.0°1 m3.28 ft2000 lx186 fc0.73 m2.39 ft2 m6.56 ft500 lx46 fc1.46 m4.78 ft3 m9.84 ft222 lx21 fc2.18 m7.16 ft4 m13.1 ft125 lx12 fc2.91 m9.55 ft5 m16.4 ft80 lx7.4 fc3.64 m11.9 ft
Cone, beam look: a spotlight's beam from the side, at each distance.
Isolux diagram at a mounting height of 4 mIlluminance below the luminaire: 125 lux. Contour lines at 100, 50, 20, 10 lux. Direct light only.-4-4-3-3-2-2-1-10011223344metres100100505020201010Mounting height 4 m · lux · Direct light onlyC0
Isolux: lines of equal light on the floor.

One file, no account: Diagrams

Many files: Sign up free

View one file

See the light output, power, efficacy and peak intensity of one file, with a drawing of its light-emitting area.

See the 3D light distribution and a lighting scene on the same page without another upload. Choose Open area, Street, Bollards, Room, Corridor, Wall or Stairs. Adjust the dimensions and read the calculated light levels. Use real light or false colour to inspect the result, and add isolux lines and a distance grid. Room and Corridor include the light that the empty room reflects; the other scenes show direct light only. Obstructions are excluded.

One file, no account: View

Compare luminaires

See two or three IES or LDT files side by side: light output, power, efficacy, beam angles, light colour, BUG rating, the polar curves and a 3D view of the light, each on one scale. Compare them in an open area, street, path, room, corridor or wall scene with the same settings and brightness scale. The light distributions, figures and polar curves stay on the same page. IES and LDT files can mix. Download a comparison as a one-page PDF for a client presentation, with Option A, B and C in place of the names or with the names, and lay the polar curves on one diagram. With an account, you can save a comparison in Your files. The files stay 30 days, and the names and figures stay after that.

Free tools: Compare

BUG Rating

Rate the backlight, uplight and glare of a luminaire against ANSI/IES TM-15-20. Rate many files and get one CSV file, with one row for each file.

One file, no account: BUG Rating

Many files: Sign up free

ULOR

Calculate the upward light output ratio: the share of the lamp light that goes above the horizontal. Get one CSV file for many files.

One file, no account: ULOR

Many files: Sign up free

Metrics CSV

Get one row for each IES or LDT file. Export BUG, LCS zones, lumens, efficacy, efficiency, uplight ratios, beam and field angles, NEMA types and road classifications. Missing values stay empty.

Start a metrics job

UGR Table

See the standard UGR table of a luminaire: 19 room sizes, five sets of room reflectances, viewed crosswise and endwise. The method is CIE 117, which EN 13032-2 requires for published UGR data.

One file, no account: UGR Table

Lighting Scenes

Open one IES or LDT file. Preview one luminaire over an open area, on a wall from the ceiling, or inside a room. Place a row of street lights beside a road, with every pole within five pole heights counted (EN 13201-3), or five bollards beside a path. Place riser lights on a straight stair, at a side wall or in the riser, and see how they light each tread. For a wall, place a row of up to 20 and read the uniformity against EN 12464-1. Preview white-light colours from warm to cool without changing the file. Search regular room layouts using copies of that product, with your target light level and uniformity. Find how many poles an open area needs, such as a car park or a yard: choose a car park class of EN 12464-2 (5, 10 or 20 lx, with uniformity 0.25) or your own targets, and see the smallest grid of poles that reaches them with direct light. Set corridor spacing and check the light at both ends. Turn the scene in 3D, show or hide the light shape at each luminaire, and point at a surface for an approximate reading. On an open area, a street, a path, a wall, in a room or in a corridor, draw isolux lines and a distance grid with their values. Read the average, minimum and maximum at the points of the calculation grid of the standard: EN 12464-1 in a room, EN 12464-2 on an open area and EN 13201-3 on a street or a path. On a street, also read the road luminance in cd/m² for a dry road surface of CIE 144 (C1, C2, R1 to R4 or N1 to N4; R1 to R4 for IES), with the uniformities, the threshold increment TI and the edge illumination ratio REI of EN 13201-3, or the RP-8 ratios for IES with the veiling luminance ratio. The search states when its time limit stops it before a confirmed result. On a street or a path, choose a lighting class and see whether the scene reaches it: the M, C and P classes of EN 13201-2, or the streets and walkways of ANSI/IES RP-8-25. In a corridor or an open area, check emergency lighting with direct light: EN 1838:2024 for an escape route or an anti-panic area, or the NFPA 101 values of an egress path for North America. In a room, set the reflectances of the ceiling, the walls and the floor: the figures include the reflected light, and an “Of which direct” row shows the direct part. The other scenes calculate direct light only.

One file, no account: Lighting Scenes, Open area, Find a pole layout, Street, Bollards, Room, Corridor, Wall, Stairs

Report sheets

Make a one-page PDF report sheet for a file, with its diagrams and its main values. There are three sheets: area and road, floodlight, and indoor. With Enterprise, add your logo, company name and footer line, and remove the IESDesk credit. With any account, make sheets for many files at once, also from files you edited, and get one ZIP file. IESDesk emails you when the sheets are ready.

One file, no account: Report sheets

Many files: Sign up free

Upload a whole folder

Drop a folder. IESDesk takes the IES and LDT files from the folder and from every subfolder, and lists each file that it leaves out.

Your files

Edit opens your files in this browser, and IESDesk does not upload them. Choose Upload to Your files instead, or Save to Your files while you edit, when you want to continue on another computer. Files that you upload, and your downloads, stay in Your files for 30 days. You can delete the files of an edit batch earlier.

Edit, View, Compare, Diagrams, BUG Rating, ULOR, UGR Table and Lighting Scenes read your files in your browser. Bulk jobs, Report sheets and the chat apps send the files to our server in Germany, which deletes them as the privacy notice says.

Learn

Guides to IES and LDT files, their dimensions, their diagrams, and the light levels of a lighting scene. Read the guides.

Free includes up to 100 files per batch or job.

Sign up with your work email